FRONT PAGE AMPYRA AUBAGIO AVONEX BETASERON COPAXONE EXTAVIA
Stan's Angels MS News Channel on YouTube GILENYA NOVANTRONE REBIF RITUXAN TECFIDERA TYSABRI
 Daily News for Neuros, Nurses & Savvy MSers: 208,152 Viewers, 8,368 Stories & Studies
Click Here For My Videos, Advice, Tips, Studies and Trials.
Timothy L. Vollmer, MD
Department of Neurology
University of Colorado Health Sciences Center Professor

Co-Director of the RMMSC at Anschutz Medical Center

Medical Director-Rocky Mountain MS Center
Click here to read my columns
Brian R. Apatoff, MD, PhD
Multiple Sclerosis Institute
Center for Neurological Disorders

Associate Professor Neurology and Neuroscience,

Weill Medical College of Cornell University

Clinical Attending in Neurology,
New York-Presbyterian Hospital
CLICK ON THE RED BUTTON BELOW
You'll get FREE Breaking News Alerts on new MS treatments as they are approved
MS NEWS ARCHIVES: by week

HERE'S A FEW OF OUR 6000+ Facebook & MySpace FRIENDS
Timothy L. Vollmer M.D.
Department of Neurology
University of Colorado Health Sciences Center
Co-Director of the RMMSC at Anschutz Medical Center
and
Medical Director-Rocky Mountain MS Center


Click to view 1280 MS Walk photos!

"MS Can Not
Rob You of Joy"
"I'm an M.D....my Mom has MS and we have a message for everyone."
- Jennifer Hartmark-Hill MD
Beverly Dean

"I've had MS for 2 years...this is the most important advice you'll ever hear."
"This is how I give myself a painless injection."
Heather Johnson

"A helpful tip for newly diagnosed MS patients."
"Important advice on choosing MS medication "
Joyce Moore


This page is powered by Blogger. Isn't yours?

Saturday

 

Choice of the pulse sequence and parameters for improved signal-to-noise ratio in T1-weighted study of MRI: STUDY





















Image Source: MEDSCAPE


Abstract

Objective:
To investigate the practical impact of alteration of imaging parameters on signal-to-noise ratio for the most commonly used T1-weighted magnetic resonance sequences.

Methods:
The study was conducted in the Department of Medical Physics, Ninewells Hospital and Medical School, Dundee, UK, in 2007. Magnetic resonance images of a tissue-equivalent material were generated with a set of T1 and T2 values. Experimental variations in the imaging parameters were performed in echo time and repetition time. Quantitative analysis consisted of signal-to-noise ratio.

Results:
Percentage inaccuracy in signal-to-noise ratio was the result of inappropriate choice of parameters. We have investigated conventional spin echo, fast spin echo and fast fluid attenuated inversion recovery with one of corresponding percentage errors 28.68%, -36.65% and -40.34%, respectively. Conventional spin echo presented moderately low percentage error with the choice of repetition time and echo time. Factual error in fast spin echo was slightly higher than conventional spin echo. Fast fluid attenuated inversion recovery could create outstanding signal-to-noise ratio of high T1/T2 value phantoms in T1-weighted images.

Conclusion:
The role of repetition time and echo time in T1-weighted images was crucial to sustain the image quality.

Story Source: The above story is based on materials provided by JOURNALOFPAKISTANMEDICALASSOCIATION
Note: Materials may be edited for content and length 
Click here to read original article